125A Invicta 3 Type B Distribution Boards
Invicta 3 type B distribution boards are the solution for modern commercial installations.
125A Distribution Boards Glazed Door
Invicta 3 (125A Incoming, 63A Outgoing)
Surface mounted steel enclosures, IP3X rated available with a glazed door. Fully shrouded copper busbar, rated 25kA short circuit conditional current. Supplied without incoming and outgoing devices. A Hager incomer kit must be used.
Incoming cable sizes
125A & 100A 50mm2
63A 25mm2
Complies with BS EN 61439-3 Annex ZB.
4, 6 & 8 way units require a JK101SE to provide additional incoming cable space.
Amendment 3 compliant units contain a full metal cover & door to comply with BS EN 61439-3 including annex ZB.
Surface mounted steel enclosures, IP3X rated available with a glazed door. Fully shrouded copper busbar, rated 25kA short circuit conditional current. Supplied without incoming and outgoing devices. A Hager incomer kit must be used.
Incoming cable sizes
125A & 100A 50mm2
63A 25mm2
Complies with BS EN 61439-3 Annex ZB.
4, 6 & 8 way units require a JK101SE to provide additional incoming cable space.
Amendment 3 compliant units contain a full metal cover & door to comply with BS EN 61439-3 including annex ZB.
125A Distribution Boards Plain Door
Invicta 3 (125A Incoming, 63A Outgoing)
Surface mounted steel enclosures, IP3X rated available with a plain door. Fully shrouded copper busbar, rated 25kA short circuit conditional current. Supplied without incoming and outgoing devices. A Hager incomer kit must be used.
Incoming cable sizes
125A & 100A 50mm2
63A 25mm2
Complies with BS EN 61439-3
4, 6 & 8 way units require a JK101SE to provide additional incoming cable space.
Amendment 3 compliant units contain a full metal cover & door to comply with BS EN 61439-3 including annex ZB.
Surface mounted steel enclosures, IP3X rated available with a plain door. Fully shrouded copper busbar, rated 25kA short circuit conditional current. Supplied without incoming and outgoing devices. A Hager incomer kit must be used.
Incoming cable sizes
125A & 100A 50mm2
63A 25mm2
Complies with BS EN 61439-3
4, 6 & 8 way units require a JK101SE to provide additional incoming cable space.
Amendment 3 compliant units contain a full metal cover & door to comply with BS EN 61439-3 including annex ZB.
125A Distribution Boards IP65
Invicta 3 (125A Incoming, 63A Outgoing)
Suitable for three phase applications where a high IP rating is required. Available with either a steel or GRP enclosure. Supplied without incoming and outgoing devices. A Hager incomer kit must be used. Steel units ending BD are not suitable for outdoor use (constructed from mild steel, powder coated).
Available up to 125A direct connection with outgoing distribution, rated for MCBs from 0.5A to 63A.
Complies with BS EN 61439-3.
Suitable for three phase applications where a high IP rating is required. Available with either a steel or GRP enclosure. Supplied without incoming and outgoing devices. A Hager incomer kit must be used. Steel units ending BD are not suitable for outdoor use (constructed from mild steel, powder coated).
Available up to 125A direct connection with outgoing distribution, rated for MCBs from 0.5A to 63A.
Complies with BS EN 61439-3.
125A Incomer Kits
These incomer kits will only fit Hager 125A boards. JK10634C & JK11004C require a 300 or 450mm space respectively below the board for fitting.
Cat ref. | Description | |||
---|---|---|---|---|
JK11003S | 100A 3 Pole JK1 Switch Incomer Kit | |||
JK11004RH | 100A 30mA 4 Pole RCCB Incomer Kit | |||
JK11004RL | 100A 300mA 4 Pole RCCB Incomer Kit | |||
JK11004RLD | 100A 300mA 4 Pole Time Delay RCCB Kit | |||
JK11004RM | 100A 100mA 4 Pole RCCB Incomer Kit | |||
JK11004RMD | 100A 100mA 4 Pole Time Delay RCCB Kit | |||
JK11004S | 100A 4 Pole JK1 Switch Incomer Kit | |||
JK11253S | 125A 3 Pole JK1 Switch Incomer Kit | |||
JK11254D | 125A Direct Connect Incomer Kit | |||
JK11254S | 125A 4 Pole JK1 Switch Incomer Kit |
125A Dual Meter Incomer Kits
Each fully assembled (distribution boards supplied separately to be assembled on site) meter pack contains; 1x incoming switch, 2x meters, 2x 3 pole CT block, 3x fuses & carriers on DIN rail, wiring loom, incoming shroud, off set incoming links, neutral connection block, extension box with glazed doors, instructions (including torque settings for electrical connections).
Cat ref. | Description | |||
---|---|---|---|---|
JKD125BMP |
125A Meter Packs
Only to be fitted into 125A boards.
This kit fits into the main distribution board (when fitting a meter pack to a JK104B(G) & JK106B(G), a JK101SE is required to provide additional incoming cable space). For sub billing metering applications please contact our Technical Service Centre on 01952 675689.
Each meter pack contains: 1x meter, 3 pole CT block, 3x fuses & carriers on DIN rail, wiring loom, incoming shroud, instructions (including torque settings for electrical connections).
This kit fits into the main distribution board (when fitting a meter pack to a JK104B(G) & JK106B(G), a JK101SE is required to provide additional incoming cable space). For sub billing metering applications please contact our Technical Service Centre on 01952 675689.
Each meter pack contains: 1x meter, 3 pole CT block, 3x fuses & carriers on DIN rail, wiring loom, incoming shroud, instructions (including torque settings for electrical connections).
Cat ref. | Description | |||
---|---|---|---|---|
JK140PM | JK1 MF Meter Pack 125A Pulsed and Modbus |
125A DIN Extension Boxes
Extension boxes are available with plain, glazed & Amendment 3 compliant doors, they contain a DIN rail chassis for mounting modular devices. Full width enclosures provide 16 modular ways per row.
Complies with BS EN 62208.
Complies with BS EN 62208.
125A Cable Spreader Boxes & Optional Door Kits
Cable spreader boxes are used for additional cabling space therefore do not require doors. If doors are desired optional door kits are available.
Complies with BS EN 62208.
Complies with BS EN 62208.
125A Side DIN Boxes
Side extension boxes provide a new concept for distribution boards to allow DIN rail mounted modular devices to be horizontally or vertically attached to distribution boards. All Side DIN Boxes come supplied with two removable gland plates.
Complies with BS EN 62208.
Complies with BS EN 62208.
125A Half Width Side Extension Boxes
Side extension boxes provide a new concept for distribution boards to allow cable ways to be fitted on site. All Side Extension Boxes supplied with two removable gland plates and can be used with Invicta 3 Panelboards JN & JF.
Complies with BS EN 62208.
Complies with BS EN 62208.
Data Logger
- Instant access and data logging plus 1 temperature input.
- Up to 8 pulsed inputs (CP1 - CP8).
- Transfer data via Ethernet, RS232/485.
- Logs up to 100 days of data from every 1 to 60 second intervals.
- DIN or direct fixing.
- 2 part terminals for easy connection.
- Works seamlessly on an Intranet with a fixed IP address.
Cat ref. | Description | |||
---|---|---|---|---|
JK107DL | 8 Input Data Logger TCP/IP Output |
Trunking Kit (100mm 4")
Each trunking kit contains a trunking channel, lid, lid joining brackets, connecting brackets and end caps.
Note: 4” trunking not suitable for JKD Power & Lighting Boards
Note: 4” trunking not suitable for JKD Power & Lighting Boards
Trunking Kit (150mm 6")
Each trunking kit contains a trunking channel, lid, lid joining brackets, connecting brackets and end caps.
Accessories
Cat ref. | Description | |||
---|---|---|---|---|
JK01B | Single Pole Busbar Blank | |||
JK030BEB | Earth Bar Hi Int, 2 x 15 Connections | |||
JK100TAP | JK 100A Top Tap Off Kit | |||
JK125BSP | 125A Single Phasing Kit | |||
JK1PLATEM | JK1 Spare Gland Plate 1.2mm | |||
JK222PK | JK1/JK2 Door Lock Kit | |||
JKLABELPACK | Spare Label Pack - All Sizes (One Pack) | |||
KRN190 | Neutral connecting block 100A |